High performance gas radiant condensation tube SolarHPRC​

”Best in class” solution for heating buildings:

  • industrial
  • tertiary
  • of large volume
  • poorly insulated
  • with high air renewal rate

Technical details

Description

  • 84% radiant efficiency
  • 103% combustion efficiency
  • Clean design
  • Available in 3 power ratings
  • Delivered with a 2 speed burner

Applications

Industrial and tertiary sector buildings with high performance requirements

Parameters

TECHNICAL CHARACTERISTICS

    SolarHPRC 12 SolarHPRC 23 SolarHPRC 36
Heat input 2nd speed kW 10.5 20 32
Heat input 1st speed kW 8 15.5 25.5
Combustion efficiency % 103 99 100
Radiant efficiency % 80 82 84
G20 gas flow rate m3/h 1.11 2.12 3.39
G25 gas flow rate m3/h 1.29 2.46 3.94
G31 gas flow rate m3/h 0.82 1.56 2.5
Gas connection 1/2” - Gas pitch male cylindrical
Flue gas evacuation/air suction mm 100
Electrical supply 1 x 230 V + N - 50 Hz
Electrical consumption A 1.5 1.5 2.1

Dimensions

    SolarHPRc 12 SolarHPRc 23 SolarHPRc 36
Length mm 3 211 5 411 7 611
Width mm 875 875 875
Height mm 280 280 360
Suspension centre distance mm 670 670 670
Cross-piece centre distance mm 2 200 2 200 (x2) 2 200 (x3)
Number of suspension points   6 8 10
Mass kg 135 195 245

References


(i.e. .doc, .pdf, .jpg, .png, .zip)

References